  • Model: B055
  • Standards: CNR N. 44 , UNE 7093 , NLT 126 , NF T66-006 , AASHTO T51 , ASTM D113 , EN 13589 , EN 13398

Equipped with incorporated refrigerating unit for tests with water temperature from + 5° to + 25°C.

Used to determine the bituminous ductility, that is the distance to which a briquette of molten bitumen can be extended under controlled conditions, before breaking. The Ductilometer basically consists of a moving carriage travelling along
guide ways. The carriage is driven by an electrical motor, inside a large tank is fitted with digital thermostat, immersion electric heater, cooling coil for cold water circulation and pump unit.
Max. traction force: 300 N, accuracy: ± 0.1 N
The ductilometer can accept up to 3 specimens simultaneously.
Supplied complete “except” for the briquette mould and base plate that must be ordered separately (see accessories).
Power supply: 230V 1 ph 50 Hz 750 W
Dimensions: 1880x360x680 mm.
Weight: 130 kg