Impact Echo System
Impact Echo System for measuring the thickness and quality of concrete.
Instr. Weight: |
6 lbs. (2.75Kg) |
Ship Weight: |
17 lbs. (7.7 Kg) |
Dimensions: |
4.5 x 8.5 x 10.5 (114.3mm x 223.5mm x 267mm) |
Freq. Range: |
0-50khz |
Impactor Sizes: |
6, 8, 10, 12, 14, & 16mm |
Gain Selection: |
0.1, 0.5, 1, 2.5, 5, 10, 25 & 50 |
Battery: |
14.4 Volt. 4-8 hours continuous use |
Display: |
320 by 240; backlit for daylight use |
Storage: |
200 plus readings |
Software: |
Windows® Compatible |
Temperature: |
0 - 50°C |
Emodumeter™
Determining Young's Modulus(E) and Poisson's Ratio
For the determination of the resonant frequency of materials.
Applications
Frequency range: |
from 10 Hz to 40 kHz |
Sampling frequency: |
10, 20, 40 or 80 kHz |
Frequency resolution: |
from 4.9 to 78.1 Hz |
Record length |
1024 or 2048 points |
Output bias level: |
9.2 V |
Accelerometer sensitivity: |
9.60 mV/g (0.979 mV/m/s2) |
Battery: |
12 Volt. 4-10 hours - continuous use |
Display: |
320 by 240; backlit for daylight use |
Storage: |
200 plus readings |
Software: |
Windows compatible 9x/me 32MB Ram |
Impactors: |
Set of 6 hardened steel balls. |
Operating Temperature Range: |
0°C to 40°C |
The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. The Pundit Lab+ comes with an extended feature set.
Pundit Lab(+)
The Pundit Lab is a flexible UPV test instrument designed primarily for operation in laboratories. It supports all traditional UPV test modes. The Pundit Lab+ comes with an extended feature set.
Automated combination of the transmitter voltage and the receiver gain for accurate and stable measurements
Open interface, can be integrated into LabView
Pundit Lab+ removes the need for external amplification when used with exponential transducers
Measuring Range |
Up to 15 m depending on concrete quality |
Bandwidth |
20 to 500 kHz |
Technology |
Ultrasonic pulse velocity |
Measuring Resolution |
0.1 us |
Pulse Voltage UPV |
125 to 500 V |
Pulse Voltage UPE |
– |
Receiver Gain |
1x, 10x, 100x, AUTO, Pundit Lab+ up to 1000x |
Nominal transducer frequency |
24 – 500 kHz |
Pulse Shape |
Square Wave |
Pulse Delay |
– |
Number Of Channels |
1 |