نفت و پتروشیمی

جستجوی تجهیزات

Petroleum Quality Analyzer

ارديبهشت 06th, 1396

New oil products grade analyzer is manufactured on the basis of advanced high precision microprocessor. the instrument can be used together with a PC a laptop through USB interface. Analyzer uses automatic computer-based calibration, saving measured data in the instrument memory with analysis date and time followed by their transfer to the PC (in Microsoft Excel or txt format). The instrument has easy of control attrition and aggressive environments resistive 8-key antiglare keyboard (made in Germany).

Analyzer SX-300 has a distinctive characteristic, an additional sensor, which measures oil products volume resistivity with high precision. Therefore, fuel analysis may be based on two values, which allows measuring octane number of petrols with ferriferous (ferrocene), nickel and manganese additives, and to determine other substances content.
By using this measurement principle the instrument allows to determine:

  • contamination content in oil products;
  • pour-point depressants content in diesel fuel;
  • engine oil base number;
  • oil products volume resistivity.

When determining petrol breakdown time, the petrol brand is selected in the instrument. The instrument switches to corresponding operating mode. Oxidative stability determination complies with GOST 4039-88 (ASTM D 525)

Motor oil brand identification is based on the permittivity determination principle. Genuine motor oils have certain value for this characteristic. Leading manufacturers’ oil brands are included into the instrument database (the database can be renewed or changed).

Water-in-oil percentage of oil and oil products is determined in compliance with GOST 14203-69 (Dielectric humidity measuring method). This allows using the instrument as a dielectric moisture indicator for oil products.

The instrument uses the timer microchip, which allows storing measurement results with analysis date and time. These data can also be transmitted to the computer.

New computer software is included into the set.
- measurement results are reflected on computer screen in convenient form;

Instrument capabilities:

  • Determining octane numbers for motor petrols. Complies with ASTM D 2699-86, ASTM D 2700-86.
  • Determining cetane numbers for diesel. Complies with ASTM D 4737-03, ASTM D 613, EN ISO 5165.
  • Determining water-in-oil percentage of oil and oil products. Complies with GOST 14203-69 Oil and oil products. Dielectric humidity measuring method.
  • Determining solidification temperature and diesel fuel type.
  • Content of antiknock compounds boosting the octane number of petrols.
  • Content of pour-point depressants for diesel fuels.
  • Content of kerosine in diesel fuel.
  • Petrol breakdown time (oxidative stability). Complies with ASTM D 525.
  • Loss angle tangent of circuit-breaker, machine and engine oil.
  • Level of engine, machine and circuit-breaker oil clarity.
  • Manufacturer, engine oil brand.
  • Engine oil base number.
  • Dielectric permeability of oil products.
  • Oil products volume resistivity.
  • Determining the mechanical impurities content in oil products.

Determining water-in-oil percentage of oil and oil products. Complies with GOST 14203-69 Oil and oil products. Dielectric humidity measuring method.

Technical characteristics

Parameter description

  Measurement units 

Value

Measured petrols octane numbers range

ON

40–125

Acceptable limit of octane number measurement basic error, max

ON

± 0.5

Limit of acceptable difference between parallel octane number measurements, max

ON

± 0.2

The determination range of antiknock additives content in petrols

%

0.5-15

Acceptable basic error limit of antiknock additives content determination in petrols

%

0.1

Petrol oxidation breakdown time measurement range

min.

50-2400

Acceptable basic error limit of petrol oxidation breakdown time

%

5

Petrol quality determination mode basing on volume resistivity

Om

10 6-10 14

Acceptable basic error limit of volume resistivity measurements

%

3

Cetane numbers measurement range

CN

20–100

Acceptable basic error limit of cetane numbers, max

CN

±1.0

Acceptable difference limit between cetane numbers parallel measurements, max

CN

± 0.5

Acceptable error limit when determining diesel-fuel pour point

C o

± 2

Kerosine content determination range in diesel fuels

%

0-95

Mode for pour point depressants content determination for diesel fuel

%

3

Acceptable basic error limit when determining kerosene content in diesel fuels

%

0.2-1

Acceptable basic error limit when determining of pour point depressants content

%

0.01

Motor oils clarity level measurement range

%

95-100

Acceptable error limit of motor oils clarity level measurement

%

0.1

Acceptable difference limit between motor oils clarity parallel measurements

%

0.01

POL dielectric permeability measurement range

Unit

1–5

Acceptable error limit of dielectric permeability measurement, max

Unit

0.001

Acceptable difference limit between POL dielectric permeability parallel measurements, max

Unit

0.001

Oils base number determination range

Unit

0-24

Acceptable basic error limit when determining oils basic number

BN unit

1

Motor oils manufacturer and brand determination

Manufacturer

-

Circuit-breaker oils (dielectrics) breakdown voltage measurement range

kV

5–100

Acceptable error limit of circuit-breaker oils breakdown voltage measurement, max

kV

1

Acceptable difference limit between circuit-breaker oils breakdown time parallel measurements, max

kV

0.2

Measurement range of circuit-breaker oils loss angle tangen

%

0.01–40

Acceptable error limit of circuit-breaker oils loss angle tangent, max

%

0.01

Acceptable difference limit between circuit-breaker oils loss angle tangent parallel measurements, max

Unit

0.001

Determination range for mechanical impurities content in oil products

%

97-100

Acceptable basic error limit when determining mechanical impurities content in oil products

%

0.01

Water-in-oil content determination range for oil products

%

0-30

Acceptable basic error limit when determining water-in-oil content of oil products

%

1

Measurement time

s

1–5

Insufficient power supply indication operation threshold

V

5.4

Instrument useful life

years

6

Overall dimensions of:

     electronic module

mm

100х210х40

     sensor #1 and #2:

mm

60х100

     Instrument mass with one sensor/two sensors

gr

850

Delivery package:

  • Electronic computing module
  • Detector #1
  • Detector #2
  • Sample imitator for detector #1
  • Software disk
  • mini-USB cable
  • Operations manual
  • Certification
  • Warranty certificate
  • Tool canvas bag

Laboratory set 2M7

ارديبهشت 06th, 1396

Portable laboratory for sample taking and on-line acceptance analysis of fuel with standard and express methods. The analysis results allow to estimate with great accuracy the fuel quality in conditions when analysis in stationary labs is not possible. The laboratory set allows to measure up 19 basic parameters of fuel quality. The test methods are as follows: Institute of Petroleum Chemistry, GOST, 25 GosNII Himmotologiyi MP RF, Joint stock company Sorbpolimer.

Technical capabilities of 2M7 lab set

Description of quality metrics

Method of testing

1.

Determination of gas octane number by motor and research methods

method of the Institute of petroleum chemistry

2.

Determination of diesel fuel cetane number

method of the Institute

3.

Determination of lead content in gas

M 32.137-9625 GosNII MO RF method

4.

Oil product density detection

GOST 3900-85

5.

Determination of mechanical impurities and water

GOST 2084-77 Paragraph 4.4

6.

Car gas color detection

Visual

7.

Content determination of heavy hydrocarbon

GOST 2084-77 Paragraph 4.7

8.

Resin content determination in gasoline

method 25 of GosNII MO RF

9.

Determination of liquid coolant content and freezing temperature by its density.

User's manual for cooling liquid handling

10.

Sampling of oil product

GOST 2517-85

11.

Quantitative determination of water in tank (tank-truck, tank wagon)

GOST 2517-85

12.

Oil product bottom sampling from tanks, and determination of settling water, and mechanical impurities.

GOST 2517-85

13.

Determination of water content in anti-crystallization additives.

GOST 8313-88

14.

Determination of anti-crystallization liquids in jet engine fuels.

Method of JSC Sorbpolimer

15.

Determination of undissolved water content

Method of JSC Sorbpolimer

16.

Determination of total water content (quantitative method)

Method of JSC Sorbpolimer

17.

Determination of acid electrolyte density

GOST 3900-85

18.

Determination of cleaning additives content in gasoline

Method 25 of GosNII MO RF

19.

Determination of ferrocene content in gasoline

Method of JSC Sorbpolimer

 Laboratory set elements

Element

measure

quantity

1.

Octane tester

set

1

2.

Sample collecting device

set

1

3.

Areometer ANT-2 0.670-0.750

pcs.

1

4.

Areometer ANT-2 0.750-0.830

pcs.

1

5.

Areometer ANT-2 0.830-0.910

pcs.

1

6.

Spare batteries

pcs.

4

7.

Graduated cylinder 100 ml

pcs.

1

8.

Graduated cylinder 250 ml

pcs.

1

9.

Areometer AON-1 1.060-1.120

pcs.

1

10.

Areometer AON-1 1.240-1.300

pcs.

1

11.

Areometer AON-1 1.360-1.420

pcs.

1

12.

Measuring beaker 100 ml

pcs.

1

13.

Water indicator paste

g.

40

14.

Evaporation bowl

pcs.

1

15.

Indicator tubes CF (yellow stripe) for detection of ferrocenes in gasoline

pcs.

10

16.

Indicator tubes TEL (red stripe) for detection of lead (tetraethyl lead) in gasoline

pcs.

10

17.

Indicator tubes WAA (no marking) for detection of fuel detergents in gasoline, water-soluble acids and alkali in light oil products

pcs.

10

18.

Indicator tubes ACL (black stripe) for detection of anticrystallizing agents in fuel for jet engines

pcs.

10

19.

Indicator tubes CW-10 (blue stripe) for detection of accumulated water in motor fuel

pcs.

10

20.

Indicator tubes CW-50 (orange stripe) for detection of dissolved water in anticrystallizing agents, alcohols, aldehydes and ketones

pcs.

10

21.

Indicator tubes UW-15 (green stripe) for detection of undissolved water in motor fuel

pcs.

10

22.

Plastic dropping pipette

pcs.

1

23.

Syringe

pcs.

5

24.

Hard Eminent case

pcs.

1

25.

Lab set documentation

set

1

26.

Ruler

pcs.

1

27.

A4 paper

set

1

28.

Pencil

pcs.

1

29.

Modeling clay

g

10

30.

Filter paper

set

1

31.

Pusher for indicator tubes

pcs.

1

32.

Bulb rubber syringe

pcs

1

33.

CITIZEN calculator

pcs

1

Documentation

Document

1.

The compound and freezing temperature test of the refrigerating fluid by its density

2.

Express method for determination of gum content in motor petrol

3.

Methods for express determination of heavy hydrocarbons content in petrol

4.

Practical recommendations for fuel density determination by areometer in accordance with GOST 3900-85

5.

Practical recommendations for fuel density determination by diagram method

6.

Practical recommendations for electrolyte density determination

7.

GOST 3900-85 Methods for determination of density

8.

Methods for express determination of detergent additive content in petrol

9.

D 1298 – 99e2 Standard Test Method for Density, Relative Density (Specific Gravity), or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method

10.

ASTM D4057 Standard Practice for Manual Sampling of Petroleum and Petroleum Products

11.

Express determination of lead content in petrol

12.

Method for determination of  ferrocene content in gasoline  (IT-CF). Certificate for IT-CF

13.

Method for tetraethyl-lead determination in motor gasoline using the indicator-adsorption method (IT-TEL). Certificate for IT-TEL

14.

Method for determination of qualitative definition of water-soluble acids and alkalis in light mineral oil ( IT-WAA ). Certificate for IT-WAA

15.

Method for determination of anti-crystallization liquids (ACL) in jet aircraft fuels using the indicator-adsorption method (IT-ACL). Certificate for IT-ACL

16.

Method for determination of water content in anti-crystallization liquids using the indicator-adsorption method (IT-CW-50). Certificate for IT-CW-50

17.

Method for determination of total water in motor fuels using the indicator-adsorption method (IT-CW-10). Certificate for IT-CW-10

18.

Method for determination of undissolved water in motor fuels using the indicator-adsorption method (IT-UW-15). Certificate for IT-UW-15

19.

Certificate for sampling unit PPN-150

20.

User manual for Octane meter

21.

Technical capabilities of laboratory set 2M7

22.

Laboratory set elements lay-out

Laboratory Set 2M7

This is aimed for sampling and carrying out commissioning tests of all kinds of fuels outside of laboratory. This laboratory set comprising octanemeter SX-100M, SX-100K, SX-200 or SX-300 analyzer.

All the necessary devices are packed in a special case. We offer you one of the most complete measuring sets for express-control over fuel quality in field conditions. Due to its small dimensions (case) as well as constant availability for service, the laboratory set provides the possibility of express-analysis of quality index for incoming fuel in any place and at the earliest possible date. The laboratory set is used for oil products sampling and seabed sampling of oil products from reservoirs. It also serves to determine the presence of sewage and mechanical impurities.

جهت تعیین سریع اکتان بنزین موتور و مناسب برای تعیین دمای مایع مورد آزمایش و سوخت دیزلی

شرایط عملکرد:

دمای محیط : ۱۰- الی ۳۰ درجه سانتی گراد

رطوبت: ۳۰ الی ۸۰ درصد

فشاری هوا : ۸۴ الی ۱۰۶ کیلو پاسکال

مشخصات فنی:

محدوده اندازه گیری میزان اکتان: ۴۰ الی ۱۲۰

محدوده انداه گیری ستان: ۲۰ الی ۱۰۰

میزان خطالی اندازه گیری : ۰/۵

مدت زمان اندازه گیری: کمتر از ۱۰ ثانیه

ساخت کمپانی Shatox روسیه