Model |
930 |
---|---|
Standard |
ASTM D56 , ASTM D3934 , ASTM D3941 , ASTM E502 , IP 491 IP 492 ISO 1516 ISO 1523 |
Tag Closed Apparatus
This test method covers the determination of the flash point, by tag manual and automated closed testers, of liquids with a viscosity below 5.5 mm2/s (cSt) at 40°C (104°F), or below 9.5 mm2/s (cSt) at 25°C (77°F), and a flash point below 93°C (200°F)
This test method covers the determination of whether a liquid complies with the closed-cup flash point requirements in government regulations, or in specifications, or as agreed between the purchaser and the seller. This test method is limited to a temperature range between 0 and 110°C (32 and 230°F
This test method covers the determination of the flash point of liquids in which the specimen and the air/vapor mixture above it are approximately in temperature equilibrium. This test method is limited to a temperature range from 0 to 110°C (32 to 230°F)
Electrically heated by electronic regulator, mounted on a case painted with anti-acid epoxidic products. Test copper cup equipped with glide device and gas or electrical ignition. Waterbath and support-jacket made in brass. With internal cooling coil.
– Temperature: from ambient to 110°C (230°F) (up to -30°C
(-22°F) with external unit)
– Power supply: 220V 50Hz
– Power: 700W
– Dimensions: 18x20x20 cm
– Weight: 6 kg