Cooling Thermostatically Controlled Water Bath, Digital
Provides water at the required temperature of 25 ±0.1°C.
The unit consists of a stainless steel water bath 18 litres capacity with wool insulation, immersion heater with digital thermostat, motor pump with connections and cooling coil device.
The bituminous sample is immersed into the water bath, and placed on the penetrometer only at the time of the test, by eventually using the transfer dish.
Cooling Thermostatically Controlled Water Bath, Digital
Provides water at the required temperature of 25 ±0.1°C.
The unit consists of a stainless steel water bath 18 litres capacity with wool insulation, immersion heater with digital thermostat, motor pump with connections and cooling coil device.
حمام آب دیجیتال (دارای سیستم خنک کننده)
دارای محفظه استیل، با قابلیت تنظیم دما در محدوده دمایی 15 تا 100 درجه سانتی گراد با دقت 0.1، دارای نمایشگر دیجیتال و پمپ سیرکوله، ساخت کمپانی ATP
حمام آب دیجیتال (دارای سیستم خنک کننده)
دارای محفظه استیل، با قابلیت تنظیم دما در محدوده دمایی 15 تا 100 درجه سانتی گراد با دقت 0.1، دارای نمایشگر دیجیتال و پمپ سیرکوله، ساخت کمپانی ATP
The equipment consists of a compact benchtop circulation cooler to be placed below the bench supporting the penetrometer: thanks to a built-in cooling compressor, temperature can be maintained in a range from 0 to 50°C with 0.1°C precision. A pump permits to circulate the liquid in the transfer dish placed on the penetrometer.
Double walled all stainless steel made, with wool insulation and water circulation electric stirrer, the bath ensures an uniform and constant temperature.
Temperature range: from ambient to +60°C. with accuracy of
+/- 0,4°C. at 20°C.
The bath is equipped with digital thermostat and a dual safety thermostat with higher thermic threshold ensuring safe working conditions.
A cooling coil device to be connected to the water net is used when room temperature exceeds the requested one, with possibility to reduce the bath temperature within the room and water net conditions.
The specimens are held by a perforated shelf spaced from the bottom.
E136-01 specifications:
Internal dimensions: 900x600x360 mm
Overall dimensions: 1050x680x430 mm
Power supply: 230V 1ph 50/60Hz 2400W
Weight: 55 kg approx.
The cooling technology of the cooling thermostats RA 8, RA 12 and RA 24 enables cooling performance through the entire temperature range of -25 up to 100 °C
Working temperature min. |
°C |
-25 |
Working temperature max. |
°C |
100 |
Ambient temperature min. |
°C |
5 |
Ambient temperature max. |
°C |
40 |
Temperature stability |
±K |
0.05 |
Cooling output at 20°C measured with ethanol |
kW |
0.23 |
Cooling output at 10°C measured with ethanol |
kW |
0.19 |
Cooling output at 0°C measured with ethanol |
kW |
0.16 |
Cooling output at -10°C measured with ethanol |
kW |
0.13 |
Cooling output at -20°C measured with ethanol |
kW |
0.08 |
Cooling output at -25°C measured with ethanol |
kW |
0.03 |
Application |
external, External and inside the bath, Inside the bath |
|
Heater power |
kW |
1.50 |
Power consumption |
kW |
1.80 |
Bath volume min. |
L |
5 |
Bath volume max. |
L |
7.50 |
Bath opening width |
mm |
165 |
Bath opening depth |
mm |
177 |
Bath depth |
mm |
160 |
usable depth |
mm |
140 |
Dimensions (WxDxH) in mm |
235x500x605 |
|
Ø nipples |
mm |
13 |
Pump pressure max. |
bar |
0.20 |
Pump flow max. (pressure) |
L/min |
15 |
The cooling technology of the cooling thermostats RA 8, RA 12 and RA 24 enables cooling performance through the entire temperature range of -25 up to 100 °C.
Working temperature min. |
°C |
-25 |
Working temperature max. |
°C |
100 |
Ambient temperature min. |
°C |
5 |
Ambient temperature max. |
°C |
40 |
Temperature stability |
±K |
0.05 |
Cooling output at 20°C measured with ethanol |
kW |
0.43 |
Cooling output at 10°C measured with ethanol |
kW |
0.37 |
Cooling output at 0°C measured with ethanol |
kW |
0.33 |
Cooling output at -10°C measured with ethanol |
kW |
0.23 |
Cooling output at -20°C measured with ethanol |
kW |
0.08 |
Cooling output at -25°C measured with ethanol |
kW |
0.02 |
Application |
external, External and inside the bath, Inside the bath |
|
Heater power |
kW |
1.50 |
Power consumption |
kW |
1.80 |
Bath volume min. |
L |
14 |
Bath volume max. |
L |
22 |
Bath opening width |
mm |
350 |
Bath opening depth |
mm |
277 |
Bath depth |
mm |
160 |
usable depth |
mm |
140 |
Dimensions (WxDxH) in mm |
415x605x605 |
|
Ø nipples |
mm |
13 |
Pump pressure max. |
bar |
0.20 |
Pump flow max. (pressure) |
L/min |
15 |
The cooling technology of the cooling thermostats RA 8, RA 12 and RA 24 enables cooling performance through the entire temperature range of -25 up to 100 °C.
Working temperature min. |
°C |
-25 |
Working temperature max. |
°C |
100 |
Ambient temperature min. |
°C |
5 |
Ambient temperature max. |
°C |
40 |
Temperature stability |
±K |
0.05 |
Cooling output at 20°C measured with ethanol |
kW |
0.33 |
Cooling output at 10°C measured with ethanol |
kW |
0.30 |
Cooling output at 0°C measured with ethanol |
kW |
0.26 |
Cooling output at -10°C measured with ethanol |
kW |
0.21 |
Cooling output at -20°C measured with ethanol |
kW |
0.08 |
Cooling output at -25°C measured with ethanol |
kW |
0.03 |
Application |
external, External and inside the bath, Inside the bath |
|
Heater power |
kW |
1.50 |
Power consumption |
kW |
1.80 |
Bath volume min. |
L |
9.50 |
Bath volume max. |
L |
14.50 |
Bath opening width |
mm |
300 |
Bath opening depth |
mm |
203 |
Bath depth |
mm |
160 |
usable depth |
mm |
140 |
Dimensions (WxDxH) in mm |
365x500x605 |
|
Ø nipples |
mm |
13 |
Pump pressure max. |
bar |
0.20 |
Pump flow max. (pressure) |
L/min |
15 |
The cooling technology of the cooling thermostats RA 8, RA 12 and RA 24 enables cooling performance through the entire temperature range of -25 up to 100 °C
Working temperature min. |
°C |
-25 |
Working temperature max. |
°C |
100 |
Ambient temperature min. |
°C |
5 |
Ambient temperature max. |
°C |
40 |
Temperature stability |
±K |
0.05 |
Cooling output at 20°C measured with ethanol |
kW |
0.23 |
Cooling output at 10°C measured with ethanol |
kW |
0.19 |
Cooling output at 0°C measured with ethanol |
kW |
0.16 |
Cooling output at -10°C measured with ethanol |
kW |
0.13 |
Cooling output at -20°C measured with ethanol |
kW |
0.08 |
Cooling output at -25°C measured with ethanol |
kW |
0.03 |
Application |
external, External and inside the bath, Inside the bath |
|
Heater power |
kW |
1.50 |
Power consumption |
kW |
1.80 |
Bath volume min. |
L |
5 |
Bath volume max. |
L |
7.50 |
Bath opening width |
mm |
165 |
Bath opening depth |
mm |
177 |
Bath depth |
mm |
160 |
usable depth |
mm |
140 |
Dimensions (WxDxH) in mm |
235x500x605 |
|
Ø nipples |
mm |
13 |
Pump pressure max. |
bar |
0.20 |
Pump flow max. (pressure) |
L/min |
15 |