Concrete

Quick Find Products

Advanced Rebar Corrosion Detector

Additional Info

  • Model: Cor-Map II
  • Standards: ASTM C876

Cor-Map II
Advanced Half Cell Potential System for Locating Areas of Rebar Corrosion with Digital Mapping Feature

Advanced System for corrosion potential data acquisition and analysis, allowing the user to quickly identify areas of probable corrosion in the field.

  • Locate corroding steel reinforcement
  • Repair cost estimation

Features & Benefits

  • Ruggedized Electronics allows rapid analysis of data in the field or office.
  • Conforms to ASTM C876 Standard Method of Half-Cell Potential of uncoated reinforcing steel in concrete.
  • Electrode is designed for use on horizontal, vertical and inverted positions.
  • Temperature and humidity sensors facilitate inclusion of environmental conditions in data analysis.

Advanced System for corrosion potential data acquisition and analysis, allowing the user to quickly identify areas of probable corrosion in the field.

Instrument Weight:

6 lbs. ( 2.75 Kg )

Ship Weight:

15 lbs. ( 6.8 Kg )

Instrument Dimensions:

4.5 in. x 8.5 in. x 10.5 in. (115mm x 225mm x 267 mm )

Battery:

12 Volt 4 - 10 Hours Continuous Operation

Display:

320 x 240 pixels backlit for daylight use

Storage:

Over 5000 readings

Operating Temperature:

0 - 50 C

Temperature Reading Range:

-273 - +130 C

Temperature Accuracy:

+/- 0.5%

Humidity Reading Range:

0 - 100%

Humidity Accuracy:

+/- 5%