Concrete

Quick Find Products

Resistivity meter

Additional Info

  • Model: Ohmcorr
  • Standards: -

Ohmcorr Test System
Resistivity Meter for Concrete

Resistivity meter to assess corrosion currents in concrete.

  • Confirm readings made with either Cor Map System

Features & Benefits

  • Assesses damaging corrosion currents in concrete.
  • Economic and easy to use.
  • Direct digital readout of resistivity. Measuring from two small holes avoids the problems and errors of surface measurements.
  • Used in conjunction with CorMap™ System to produce resistivity plots.

·         RESISTIVITY LEVEL

·         (K OHMS CM)

·         <5

·         5 to 10

·         10 to 20

·         >20

POSSIBLE CORROSION RATE OF

REINFORCEMENT REBARS

Very High

High

Moderate to Low

Insignificant

The James OhmCorr™, when used in conjunction with the James CorMap™ System provides an economic and sound means of diagnoses of corrosion in reinforced concrete.

Specifications

Weight complete in carrying case

8 lbs (4 kilos)

Display:

4-1/2” Digit in LCD

Resolution:

± 0.1K ohms cm (± 1 Digit)

Range:

0.5 - 20K ohms cm

Battery:

9 Volt

  •