Petroleum

Quick Find Products

Mahler Cylinder

December 05th, 2017

This test method covers the determination of sulfur in petroleum products, including lubricating oils containing additives, additive concentrates, and lubricating greases that cannot be burned completely in a wick lamp. The test method is applicable to any petroleum product sufficiently low in volatility that it can be weighed accurately in an open sample boat and containing at least 0.1% sulfur.

Capacity 300ml, completely made in stainless steel included the two electrodes, cover with threaded displacing ring, gasket around the cover edge, an automatic inlet valve, a pin exhaust valve. Tested at 200 bar/20 MPa.

- Dimensions: Ø10x22 cm
- Weight: 4.5 kg